Quiz NFPA - High Hit-Rate Top CFI-I Questions
Quiz NFPA - High Hit-Rate Top CFI-I Questions
Blog Article
Tags: Top CFI-I Questions, Valid CFI-I Mock Test, Exam CFI-I Tips, CFI-I Online Lab Simulation, CFI-I Latest Dumps Free
The policy of "small profits "adopted by our company has enabled us to win the trust of all of our CFI-I customers, because we aim to achieve win-win situation between all of our customers and our company. And that is why even though our company has become the industry leader in this field for so many years and our CFI-I Exam Materials have enjoyed such a quick sale all around the world we still keep an affordable price for all of our customers and never want to take advantage of our famous brand.
Our CFI-I exam questions have a lot of advantages. First, our CFI-I practice materials are reasonably priced with accessible prices that everyone can afford. Second, they are well-known in this line so their quality and accuracy is unquestionable that everyone trusts with confidence. Third, our CFI-I Study Guide is highly efficient that you have great possibility pass the exam within a week based on regular practice attached with the newest information.
Top Top CFI-I Questions Pass Certify | High Pass-Rate Valid CFI-I Mock Test: Certified Fire Inspector I (CFI-1)
The aim of ITexamReview is to support you in passing the NFPA CFI-I certification exam. ITexamReview present actual NFPA CFI-I practice test questions for you. The world's skilled professionals share their best knowledge with ITexamReview and create this set of actual Certified Fire Inspector I (CFI-1) CFI-I
NFPA CFI-I Exam Syllabus Topics:
Topic | Details |
---|---|
Topic 1 |
|
Topic 2 |
|
Topic 3 |
|
Topic 4 |
|
NFPA Certified Fire Inspector I (CFI-1) Sample Questions (Q49-Q54):
NEW QUESTION # 49
What is the minimum diameter allowed for piping serving fire hydrants on private fire service mains?
- A. 8 in. (203.2 mm)
- B. 10 in. (254 mm)
- C. 4 in. (101.6 mm)
- D. 6 in. (152.4 mm)
Answer: D
Explanation:
Comprehensive and Detailed Step-by-Step Explanation:
Fire Hydrant Piping Diameter:
Per NFPA 24 (Standard for the Installation of Private Fire Service Mains and Their Appurtenances), Section 5.2.1, the minimum diameter for piping serving fire hydrants on private fire service mains is 6 inches (152.4 mm).
Why 6 Inches is Required:
A minimum 6-inch pipe ensures sufficient water flow and pressure to meet firefighting demands.
Other Options Explained:
Option A (4 in): Too small; insufficient for hydrant water supply.
Option C (8 in) and Option D (10 in): Acceptable but exceed the minimum requirement.
Summary:
The minimum diameter for piping serving fire hydrants on private fire service mains is 6 inches (152.4 mm).
NEW QUESTION # 50
What is the color of the glass bulb in a 155°F (66°C) temperature-rated sprinkler head?
- A. Orange or red
- B. Blue
- C. Purple
- D. Yellow or green
Answer: A
Explanation:
The color of the glass bulb in sprinkler heads indicates the temperature rating at which the bulb will activate. These colors are standardized under NFPA 13:
155°F (66°C) temperature-rated sprinklers are classified as Ordinary temperature range, and the glass bulb is typically orange or red.
The colors correspond to the following:
Orange/Red: 135°F-155°F (57°C-68°C)
Yellow/Green: 175°F-225°F (79°C-107°C)
Blue: 250°F-300°F (121°C-149°C)
Purple: 325°F-375°F (163°C-191°C)
Reference:
NFPA 13, Table 7.2.2.1: Sprinkler temperature ratings and corresponding bulb colors.
NEW QUESTION # 51
What is the maximum occupant load for a conference room with a total area of 900 ft² (84 m²)?
- A. 120 people
- B. 30 people
- C. 90 people
- D. 60 people
Answer: D
Explanation:
Comprehensive and Detailed Step-by-Step Explanation:
Occupant Load Calculation:
According to NFPA 101 (Life Safety Code), Table 7.3.1.2, for assembly occupancies without fixed seating (such as conference rooms), the occupant load factor is:
15 ft² (1.4 m²) per person.
Calculation:
Divide the total area of 900 ft² by 15 ft per person: 900ft2/15ft2/person=60people900 , text{ft}